Manhattan San Francisco Oʻahu Oʻahu Kauaʻi Molokaʻi Lānaʻi Maui Hawaiʻi PON 6162 · Hawaiʻi · Hawaiian Electric · an island grid
Oʻahu, a battery in every home An island that burns oil for its evenings: homes cooling with window units, or not yet at all — the fleet soaks up the midday sun and carries the evening peak.
The day in figures More
Peak relief 144 MW
Peak · Airform 1,157 MW
CO₂ today · Airform 12k t
Peakers run 344 MWh Three ways the city could go Window ACs todaypeak 1,180 MW CO₂ 11k t a day no load shed Ordinary heat pumpspeak 1,301 MW CO₂ 13k t a day no load shed Airform + battery fleetpeak 1,157 MW CO₂ 12k t a day no load shed
Airform in the homes, a battery in each: charged from the midday sun, spent on the evening.
The fleet Airform in the island's homes 25% · 105,000 units 0% 100% Battery in each unit None 2.2 kWh 5 kWh
Facade modules on the units 40% 0% 100% Demand-response event called 17:00–21:00 · the fleet spends its reserve
Units 105,000 · 0% of homes' buildings
Stored at the point of load 525 MWh
Peakers avoided a day 634 MWh
Facade sun a day 196 MWh · no interconnection
Electrical upgrades avoided $126M
Outage ride-through 3.5 hours How this is drawn and what it assumes 350,000 homes and 420,000 room units' worth of window air conditioners — and the homes that don't have any yet. Oʻahu is an island grid: no imports, oil-fired steam at Kahe, Waiau and Kalaeloa, oil peakers at Campbell Industrial Park and Schofield, and the new island of solar farms, wind and the Kapolei grid battery, whose output follows the sun. Rooftop solar empties the middle of the day; the evening comes back steep and oil carries it. The buildings are the City and County of Honolulu's own footprints, with their measured heights, on the island's real ground — the Koʻolau and the Waiʻanae, Diamond Head and Pearl Harbor; the substations stand in for Hawaiian Electric's by name and rough place. The neighbour islands are a menu away.
An illustrative model after the PON 6162 proposal, not a utility study. Each Airform discharges up to 1.6 kW, keeps 20% in reserve on an ordinary day, and aims to take 60% of its peak off (85% in an event); facade solar is a 120 W vent plus 1,080 W of modules where fitted, behind the appliance. CO₂ counts the grid, in merit order, and the gas still burned for heat. The electrons are a picture of the flows, not a load-flow: the fleet's dispatch is drawn running back up the feeders, but it stays behind the meter — nothing is exported.